The Aurora System

Sale price$5,175.00 USD

Insulated acrylic tub paired with the Borealis™ Heater & Chiller. Built with double-walled thermal foam and available in three sizes for a tailored fit.

Aurora 2 (Size): Small
Aurora 2 (Color): White (Standard)
Borealis™ (Select Your Engine): Gen 4: Standard (0.8HP)
Re-stocking soon

The Aurora System

The Aurora System: Complete Climate Control
Transform your recovery routine with the Aurora System—a fully integrated cold and hot therapy suite designed for home and commercial use.

Dual-Action Power Paired with our powerful Borealis™ Heater & Chiller (Gen 4 or Gen 5), this system delivers precise temperatures from 3°C to 42°C on demand.

Thermal Efficiency Built with a premium double-walled acrylic shell and injected with high-density insulation foam. This superior construction locks in thermal energy, drastically reducing electricity costs while keeping your water ready whenever you are.

Tailored to Your Space Available in Small, Regular, and Large, the Aurora is engineered to fit your specific height and available floor space without compromising on depth or comfort.

Plug & Plunge No complex plumbing required. Simply connect the hoses, plug into a standard outlet, and take control of your recovery.

Key Benefits

Heating & Cooling

Delivers precise cooling down to 3°C and heating up to 42°C with the integrated Borealis™ system.

Refined Dual-Wall Insulation

Engineered with a robust dual-wall structure that maintains stable water temperature and maximizes cooling efficiency in any environment.

Advanced Ozone Sterilization

Commercial grade Ozone sanitation system keeps water clean and bacteria-free for safe and hygienic use.

Efficient Filtration

Features a 20-Micron filter cartridge system for clean, clear water and reduced maintenance.

Touch Panel with Wi-Fi and Smart App Control

Adjust temperature, modes, and schedules seamlessly through the Smart Life app.

Adaptive Sizing for Perfect Fit

Available in Small, Regular, and Large to accommodate different body types, spaces, and recovery preferences without compromising immersion depth.

Experience 3°C to 42°C precision in a stunning, double-walled acrylic shell designed to last a lifetime.

Recovery, Refined.

Everything you need for immediate setup.

What’s Included

  • Aurora Solid Dual Wall Insulated Tub
  • Insulated Hard Cover (Locks in thermal energy)
  • 10m Utility Hose (Quick-connect for easy filling & draining)
  • Drainage System

Return to Yourself

20%

reduction in muscle soreness

30%

faster recovery

300%

increase in norepinephrine

Product specification

Dimensions

The Aurora Tub:

- Small: LxWxH: 150 x 75 x 58 CM
- Regular: LxWxH: 160 x 75 x 58 CM
- Large: LxWxH: 170 x 80 x 60 CM

Borealis™ Heater & Chiller:
- Gen 4: Standard (0.8HP): LxWxH: 51 x 34 x 54 cm
- Gen 4: Turbo (2.0HP): LxWxH: 68 x 49 x 75
- Gen 5: Pro (1.0HP): LxWxH: 53 x 38 x 57
- Gen 5: Elite (2.0HP): LxWxH: 68 x 49 x 75

Water Capacity

Small: 210 L; Regular: 230 L; Large: 250 L;

Temperature Range

3°C to 42°C (Cooling + Heating)

Compressor / Heater & Chiller:

Gen 4: Standard (0.8HP):
- Compressor power: 605 W
- Cooling capacity: 2,090 W
- Heating capacity: 2,505 W
- Refrigerant: R410A (320 g)

Gen 4: Turbo (2.0HP):
- Compressor power: 1,660 W
- Cooling capacity: 5,000 W
- Heating capacity: 5,800 W
- Refrigerant: R410A (480 g)

Gen 5: Pro (1.0HP):
- Compressor power: 900 W
- Cooling capacity: 2,450 W
- Heating capacity: 3,800 W
- Refrigerant: R410A (360 g)

Gen 5: Elite (2.0HP):
- Compressor power: 1,660 W
- Cooling capacity: 5,000 W
- Heating capacity: 5,800 W
- Refrigerant: R410A (480 g)

Cooling/Heating Performance

Small – 210 L

* Gen 4: Standard (0.8HP)
Cooling: ~8.0-9.5°C per hour
Heating: ~9.5-11.0°C per hour

* Gen 4: Turbo (2.0HP)
Cooling: ~18-21°C per hour
Heating: ~21-24°C per hour

* Gen 5: Pro (1.0HP)
Cooling: ~8.5-10.0°C per hour
Heating: ~13-15°C per hour

* Gen 5: Elite (2.0HP)
Cooling: ~18-21°C per hour
Heating: ~21-24°C per hour

Regular – 230 L

* Gen 4: Standard (0.8HP)
Cooling: ~7.0-8.5°C per hour
Heating: ~8.5-10.0°C per hour

* Gen 4: Turbo (2.0HP)
Cooling: ~16-18°C per hour
Heating: ~19-21°C per hour

* Gen 5: Pro (1.0HP)
Cooling: ~7.5-9.0°C per hour
Heating: ~11.5-13.5°C per hour

* Gen 5: Elite (2.0HP)
Cooling: ~16-18°C per hour
Heating: ~19-21°C per hour

Large – 250 L

* Gen 4: Standard (0.8HP)
Cooling: ~6.5-7.5°C per hour
Heating: ~7.5-8.5°C per hour

* Gen 4: Turbo (2.0HP)
Cooling: ~14.5-16.5°C per hour
Heating: ~17-19°C per hour

* Gen 5: Pro (1.0HP)
Cooling: ~7.0-8.0°C per hour
Heating: ~10.5-12.5°C per hour

* Gen 5: Elite (2.0HP)
Cooling: ~14.5-16.5°C per hour
Heating: ~17-19°C per hour

About these values

These figures are realistic estimates for continuous operation under typical conditions. Actual cooling and heating performance may vary depending on ambient temperature, sun exposure, wind, insulation quality, use of the cover, plumbing length, circulation rate, and heat introduced by users.

FAQ

Use this text to share information about your product or shipping policies.

Our customer support is available Monday to Friday, 9am–6pm SGT and Saturday, 9am-12pm SGT.Average answer time: within 24h
Email us